Blast Resistant Buildings, Fire Resistant Buildings & Seismic Rated Buildings & Shelters
Bookmark Us Contact Us
Use this secure link to chat or leave a message now!
BLAST RESISTANT BUILDINGS SECTION
Blast Resistant Buildings, Fire Resistant Buildings & Seismic Rated Buildings & Shelters

Blast Resistant Buildings
Engineering Certification

We truly understand the critical nature of your concerns...

Bebco has been located near Houston, Texas for over 40 years, in the heart of a very large petrochemical refining industry on the Gulf Coast.   Consequently, many of our staff members and our owners have experienced the tragedies of cataclysmic refinery explosions and rebuilt their homes and lives after enduring the torrential forces of major hurricanes.  Therefore, we strive to ensure that the integrity of our Blast Resistant Buildings is unquestioned and the quality of our products is never compromised by competitive desires.
Blast Resistant Buildings from Houston, Texas
Blast Resistant Buildings from the World's Energy Capitol
Third-Party Engineering Philosophy...

Bebco proudly utilizes the services of Hopper Engineering Associates, in Redondo Beach, California, to independently verify the integrity of all Blast Resistant Buildings Bebco manufactures. Among the most prestigious certified engineering firms we use, Hopper verifies that our Blast Resistant Buildings meet the stringent requirements to withstand blasts, fires, forced entry, seismic events, hurricanes and tornados.  As a result, you receive competent engineering from unbiased third parties and effective manufacturing results from Bebco; without the associated overhead of maintaining an in-house engineering staff that could never rival the vast expertise we draw from firms like Hopper Engineering on a daily basis.
 

Hopper Engineering Associates

A Nationally Recognized & Independently Certified Firm
Certified Welding, Inspection & Quality Assurance Programs...

To complement our third-party engineering philosophy, Bebco employs a quality driven staff of independently certified welders to maintain absolute compliance with regard to the most critical aspect of our Blast Resistant Buildings.  In addition, we retain several in-house inspectors that are certified by the American Welding Society and the City of Los Angeles, California. Together, these entities demand extremely stringent compliance to industry standards and facilitate Bebco's ability to sustain a high standard of quality control.
Blast Resistant Buildings - Mig Welding Technology

Welder, Inspection & Quality Assurance Certifications are available upon request.
Please contact a Bebco Salesperson for more information.

Comprehensive Code Compliance Capabilities...

In addition to complying with all design specifications we receive for your blast resistant building, Bebco is fully capable of manufacturing blast resistant buildings in accordance with and to meet or exceed any domestic or international code, standard or recommended practice, including but not limited to the following publications:

2009 International Code Council (ICC) - International Fire Code (IFC)
2009 International Code Council (ICC) - International Building Code (IBC)
2009 American Petroleum Institute (API) Standard 752 - Management of Hazards Associated with Location of Process Plant Permanent Buildings
2008 National Fire Protection Agency (NFPA) Code 70 - National Electrical Code (NEC)
2008 National Fire Protection Agency (NFPA) Standard 496 - Standard for Purged and Pressurized Enclosures for Electrical Equipment
2007 American Petroleum Institute (API) Standard 753 - Management of Hazards Associated with Location of Process Plant Portable Buildings
2007 U.S. Army Corps of Engineers Document PDC-TR 06-08 - Single Degree of Freedom Structural Response Limits for Antiterrorism Design
2006 Process Industry Practice (PIP) Standard STC01018 - Blast Resistant Building Design Criteria
1997 American Society of Civil Engineers (ASCE) - Design of Blast Resistant Buildings in Petrochemical Facilities
1990 Department of the Army; Technical Manual TM 5-1300; Structures to Resist the Effects of Accidental Explosions
  < See note below

The last hyperlink above will download a 73.04 Mb PDF document from the Pentagon - patience is required!
Each link above provides detailed information and serves as a potential source to purchase or acquire the publication.
Please therefore utilize these links with careful discretion and note Bebco offers no guarantee of publication authinticity.


All blast resistant buildings manufactured by Bebco are then equipped with blast resistant doors and blast resistant windows from fully qualified manufacturers who produce and certify their products to meet numerous performance standards including but not limited to these publications:
 
UL 9 - Fire Tests of Window Assemblies NIJ 0101.04 - Standard for Bullet Resistance
UL 1784 - Air Leakage Tests of Door Assemblies ANSI/UL 10B - Fire Tests of Door Assemblies
UL 752 - Standard for Bullet-Resisting Equipment NFPA 252 - Standard Methods of Fire Tests of Door Assemblies
UL Subject 63 - Outline of Investigation for Fire Door Frames CAN4-S104-M80 - Standard Method for Fire Tests of Door Assemblies
ANSI/UL 10C - Positive Pressure Fire Tests of Door Assemblies NFPA 257- Standard on Fire Tests for Window & Glass Block Assemblies
ASTM F588 - Standard Test Methods for Measuring the Forced Entry Resistance of Window Assemblies, Excluding Glazing Impact
ASTM F1233 - Standard Test Method for Security Glazing Materials And Systems
ASTM F476 - Standard Test Methods for Security of Swinging Door Assemblies

At Bebco, the integrity of our blast resistant buildings is ensured not only by us,
but also by independent experts, all working together to guarantee your safety!

Blast Resistant Buildings, Fire Resistant Buildings & Seismic Rated Buildings & Shelters
4725 Lawndale - La Marque, Texas 77568 - U.S.A.
Phone: (409) 935-5743 Fax: (409) 938-4189
Business Hours: 8 a.m. to 5 p.m. CST, Monday-Friday
Please feel free to e-mail our to address
any issues, questions or comments about this Website.
Terms of Use  Publication Date: 10.01.11  Site Map